Online Inquiry

Please note that we are not a pharmacy or clinic, so we are unable to see patients and do not offer diagnostic and treatment services for individuals.

Vitamin B12 test kit

Rat adrenocorticotropic hormone (ACTH) CLIA kit

Cat. No.: OB0125WXX-028
Assay Type: Competitive inhibition CLIA
Target Species: Rat
Assay Target: ACTH
Size:
Rat adrenocorticotropic hormone (ACTH) CLIA kit

Product Overview

Description: Rat adrenocorticotropic hormone (ACTH) CLIA kit is a CLIA kit assay for the detection of rat ACTH levels. The range of the assay is 11.72-3000 pg/mL.
Assay Principle: The microtiter plates in this kit are pre-coated with a monoclonal antibody specific for ACTH. A competitive inhibitory reaction occurs between biotin-labeled ACTH and unlabeled ACTH (standards or samples) and the pre-coated ACTH-specific antibody. After incubation, the unbound conjugate is washed away. Avidin conjugated to horseradish peroxidase (HRP) is then added to each microtiter well and incubated. The amount of bound HRP is inversely proportional to the concentration of ACTH in the sample. A mixture of substrates A and B is then added to produce glow emission kinetics. After development, the intensity of the glow is inversely proportional to the amount of ACTH in the sample or standard.
Background: ACTH stimulates the adrenal glands to release cortisol. Defects in POMC may be associated with susceptibility to obesity (OBESITY). It is a condition characterized by an increase in body weight beyond the limitations of skeletal and physical requirements, as a result of excessive accumulation of body fat. Defects in POMC are the cause of pro-opiomelanocortinin deficiency (POMCD). Affected individuals present early-onset obesity, adrenal insufficiency, and red hair.
Synonyms: ACTH; Corticotropin; Adrenocorticotropin; Adrenocorticotropic hormone; Pomc1; Pomc-1; Beta-LPH; AlphaMSH; beta-MSH; Gamma-LPH; Alpha-MSH; Gamma-MSH
Applications: Rat adrenocorticotropic hormone (ACTH) CLIA kit is used to detect rat ACTH levels in serum, plasma, and other biological fluid samples by chemiluminescent immunoassay.
Research Area: Hormone research; Circadian rhythm; Obesity

Specification

Sample Type: Serum; Plasma; Other biological fluids
Detection Range: 11.72-3000 pg/mL
Sensitivity: 4.52 pg/mL
Precision (Intra-assay): CV<10%
Precision (Inter-assay): CV<12%
Cross-reactivity: No significant cross-reactivity or interference was observed.
Storage: Store at 2-8°C.
Inquiry

Copyright © Protheragen. All rights reserves.

x thanks giving